Hot Water Recirculation Systems
The Metlund® Hotwater D'Mand® System
The Metlund® Hot Water D'MAND® System consists of an electronically
controlled pump and valve assembly that allows for the rapid delivery of
hot water to plumbing fixtures without the loss of cold water down the
drain.
The D'MAND System is activated when someone creates a demand for hot water
by activating the pump with any one of a number of methods. At that time,
the Hot Water D'MAND System pumps the hot water to the plumbing fixtures.
Once hot water reaches the pump, the System detects a 3° to 4° temperature
rise and completely shuts off so there is no loss of energy or water!
|
The Metlund D'MAND System is the only UL Listed and Uniform
Plumbing Code Listed hot water distribution system that is
recognized by the US Department of Energy to save both water
and energy. |
 |
Its features include:
- Automatic "fail-safe"
- 3-year (S-50) or 5-year (S-70T and S-02) warranty
- Life expectancy 15 to 20 years
- Less than $1.00 a year to operate
- Delivers hot water within seconds to more than one fixture
- Delivers hot water without wasting cold water down the drain
- System only operates when there is a demand for hot water
- Simple installation for new and existing homes
- Works with all standard water heaters (gas, electric, tankless,
or propane)
- Title 24 Compliance (CA only)
- "No Sweat" easy installation package available with
optional remote control button
- IAPMO "Uniform Plumbing Code" approved
- UL Listed
How it works
At the push of a button, the Metlund® Hot Water D'MAND® System
circulates the ambient temperature water in the hot water pipes (water
that is normally lost down the drain) back to the water heater. This
occurs up to 80% faster than just letting the water run down the
drain—the usual scenario. Depending on the plumbing layout,
the route and time can vary. The Metlund D'MAND System moves the
water so rapidly, that hot water arrives at the fixtures before the
heat is lost through the pipe.
As the ambient temperature water in the cold water line travels
towards the hot water heater, the D'MAND System fills the hot water
line with hot water. When the hot water reaches the D'MAND System,
a thermal sensor (thermistor) senses a temperature rise and quickly
closes the zone valve while it shuts the pump off. The sophisticated
electronic circuitry that does this is attached to the high-performance
pump housing.
This results in getting hot water to the fixtures four to five times
quicker (on average), greater convenience in not having to wait,
a savings in water and energy, and a reduction in sewage costs. As
a by-product of these savings, a cumulative result is the improvement
of air quality.
The Metlund D'MAND System can utilize the cold water line as a return
line or use a dedicated return line. By using the existing cold water
line, it is easy to retrofit existing homes or businesses. Special
plumbing is not needed, and since the System will not allow for hot
water to cross over to the cold water line, all the cold water fixtures
still have cold water. |